What is the main difference between vapour compression and vapour absorption refrigeration cycle

Difference between Vapour absorption refrigeration system and vapour compression refrigeration system:

Vapour Absorption refrigeration system:

  • Vapour absorption refrigeration system has less maintenance.
  • It has less wear comparatively than compression refrigeration system.
  • It produces low sounds at the time of operation.
  • This type of refrigeration system has small motors than the compression type.
  • In vapour absorption refrigeration system has no moving parts in it.
  • Vapour absorption refrigeration system is operated under designed COP.
  • This type of system the capacity is not decreased when there is even decreases in pressure, because it can be controlled.
  • The performance of the vapour absorption system has no changes even there is any variation in load.
  • This type of system is used for large capacity works.

What is the main difference between vapour compression and vapour absorption refrigeration cycle

Vapour Compression Refrigeration System:

  • This type of refrigeration system required more maintenance.
  • It is subjected to more wear than the absorption refrigeration system.
  • This type of system generates more noise at the time of operation.
  • Compression refrigerator has large motor than absorption system.
  • This type of system has no constant COP to operate it varies according to the evaporator conditions.
  • The capacity is decreased in this system when the pressure of the evaporator decreased.
  • The performance is not stable and poor at the time of variation in load.
  • Vapour absorption refrigeration system is used for less capacity works.

We have seen various types of absorption refrigeration systems like simple absorption cycle, ammonia-water absorption cycle and also the vapor compression refrigeration cycle. Let us see the comparison of the vapor absorption cycle and vapor compression cycle. First let us see the advantages of absorption refrigeration system and then we shall see the disadvantages of absorption refrigeration system over vapor compression system.

Advantages and Comparison of Vapor Absorption Refrigeration over Vapor Compression Refrigeration

Here are of the comparisons and advantages of absorption refrigeration system over vapor compression refrigeration system:

1) Method of compression of the refrigerant: One of the most important parts of any refrigeration cycle is the compression of the refrigerant since all the further operations depend on it. In the vapor compression refrigeration system the compression of the refrigerant is done by compressor which can be of reciprocating, rotating or centrifugal type. In the vapor absorption refrigeration system, the compression of the refrigerant is done by absorption of the refrigerant by the absorbent. As the refrigerant is absorbed, it gets converted from the vapor state to liquid state so its volume reduces.

2) Power consumption devices: In the vapor compression cycle the compressor is the major power consuming device while in the vapor absorption cycle the pump used for pumping refrigerant-absorbent solution is the major power consuming device.

3) The amount of power required: The compressor of the vapor compression cycle requires large quantities of power for its operation and it increases as the size of the refrigeration system increases. In case of the vapor absorption refrigeration system, the pump requires very small amount of power and it remains almost the same (or may increase slightly) even for higher capacities of refrigeration. Thus the power consumed by the vapor absorption refrigeration system is much more than that required by the vapor compression system.

4) Type of energy required: The vapor absorption system runs mainly on the waste or the extra heat in the plant. Thus one can utilize the extra steam from the boiler, or generate extra steam for the purpose and also use the hot available water. Similarly the waste heat from the diesel engine, hot water from the solar water heater, etc. can also be utilized. In case of the vapor compression refrigeration system, the compressor can be run by electric power supply only; no other types of energy can be utilized in these systems.

5) Running cost: The vapor compression refrigeration system can run only on electric power, and they require large amount of power. These days the electric power has become very expensive, hence the running cost of the vapor compression refrigeration system is very high. In case of the absorption refrigeration system only small pump requires electric power and it is quite low. In most of the process industries, where the absorption refrigeration is used, there is some extra steam available from the boiler, which can be used for running the system. Thus in absorption refrigeration system no extra power in the pure electric form is required and the energy that would have otherwise gone wasted is utilized in the plant. Thus the running cost of the absorption refrigeration system is much lesser than the vapor compression system.

6) Foundations required and noise: The compressor of the vapor compression system is operated at very high speeds and it makes lots of vibrations and noise. It also requires very strong foundation so that it can remain intact under vibrations and high pressures of the refrigerant. In the absorption refrigeration system there are no major moving parts hence they don’t vibrate, don’t make noise and also don’t require heavy foundations. The absorption refrigeration systems operate silently.

7) Maintenance: Compressor is the crucial part of the vapor compression cycle, and it has number of moving parts. It is very important to do the thorough lubrication of the compressor and also keep checking it regularly for any defects. The compressor also requires changing of the piston, piston rings, cylinder liner etc. from time-to-time. Thus the vapor compression system requires lots of maintenance. Failure of compressor can be very expensive at times as the suction and the discharge valve of the compressor are very expensive. Even the motor of the compressor is very heavy and expensive. The compressor also requires cooling, for which special pump is required to pump the water from the cooling tower to the compressor. Since there are number of moving parts of the compressor that move at very fast speed some or the other failure occurs regularly. In the absorption refrigeration system the only moving part is the small pump that fails rarely. Thus the maintenance required by the vapor compression system is much more than that required by the vapor absorption system.

8) Capacity control of the system: In the vapor compression cycle the capacity control of the system is done from the compressor and in most of the cases stepwise capacity control is obtained. In case of the absorption refrigeration system it is possible to obtain stepless capacity control and zero capacity when there is no load on the system. Though these days compressors with stepless capacity control are available, but they will consume lots of power even if there is zero load on the refrigeration system. In absorption system, when there is zero load the power consumption is almost zero.

9) Type of refrigerant used and its cost: In ammonia-water absorption refrigeration system, ammonia is used as the refrigerant, which is easily and cheaply available. In lithium bromide system, water is used as the refrigerant, which is also available cheaply and easily. In case of the vapor compression refrigeration system halocarbons are used as the refrigerants, which are very expensive.

10) Leakage of the refrigerant: In the absorption refrigeration system there are no (or very few) leakages of the refrigerant and the refrigerant itself is very cheap. Thus there are almost zero refrigerant recharging costs. In case of the vapor compression systems there are lots of leakages of the refrigerant thus regular recharge of the refrigerant is required which is very expensive.

11) Greenhouse effect: Most of the halocarbon refrigerants used in the compression refrigeration system produces greenhouse effect. As per the Montreal Protocol, their use has to stop completely by the year 2020. In the absorption refrigeration system no refrigerant produces the greenhouse effect, so their use won’t be stopped in future.

1) Initial capital cost: Though the running cost of the absorption refrigeration system is much lesser than the vapor compression system, its initial capital cost is much higher.

2) Corrosive nature of lithium bromide: In the lithium bromide absorption refrigeration system, lithium bromide is corrosive in nature, which reduces the overall life of the system. In case of the ammonia system, ammonia is corrosive to copper. In the vapor compression system copper is used with the halocarbon refrigerants and they are quite safe thus ensuring long life of the refrigeration system. As such the vapor compression system with reciprocating or centrifugal compressor has longer life than the lithium bromide absorption refrigeration system.

3) Low working pressures: The working pressures of the absorption refrigeration cycle are very low. In case of the lithium bromide system these pressures are so low that even the expansion valve is not required since the drop in pressure of the refrigerant due to its flow is good enough to produce its expansion. Due to this the refrigeration system should be sealed thoroughly so that no atmospheric gases would enter the refrigeration system. As such the system of the compression refrigeration should also be packed tightly, but this is to prevent the leakage of the refrigerant to the atmosphere.

4) Coefficient of Performance (COP): The coefficient of performance of the absorption refrigeration systems is very low compared to the vapor compression systems. For instance, the COP of the two stage lithium bromide system is about 1.1, while that of the vapor compression system used for the air conditioning applications it is about 4 to 5. Thus the absorption refrigeration system becomes competitive only if the ratio of the electricity to fuel (oil, gas or coal used to generate the steam in the boiler) becomes more than four. If this ratio is lesser there are chances that excess fuel would be required to generate the steam. However, if there is excess steam in the industry, this ratio may not be given importance.

5) Higher heat rejection: In the absorption refrigeration heat has to be rejected from number of parts like condenser, absorber, analyzer, rectifier etc. thus heat rejection factor for absorption refrigeration system is high and it can be around 2.5. In the compression refrigeration system the heat is given up only from the condenser, so it heat rejection factor is small, which is about 1.2. Thus the cooling tower and pump capacities for pumping the cooling water have to be higher in case of the absorption refrigeration system, which leads to increase in the running cost of the system.

Reference

Book: Basic Refrigeration and Air Conditioning by P N Ananthanarayanan, Tata McGraw-Hill Publishing Company Limited